Flow Matric

Automatic air valves, with double orifice and integrated valve, flanged PN 16, 25

Article: 706-712
Flanges: UNI EN 1092-2 PN 16-25
Installation: at the high part of pipelines
APPLICATIONS • Aqueducts • Irrigation plants
– Fig. 706: flanges drilling PN 16
– Fig 712: Flanges drilling PN 25
Epoxy paiting suitable for drinking water applications.

The double orifice automatic air valves with integrated valve are used for applications related to troubles with air in the pipelines. The double air valves with integrated valve working as isolating valve allow maintenance or replacement of balls in line.
The minimum pressure on seat is 0,3 bar.

The double ball air valves have three functions:

  1. Discharge large amount of air during filling operations
  2. Discharge small amount of air during working operations
  3. Let air in during piping emptying operations

Materials

body

ductile iron GGG40/50, EN-GJS-400/500

cover

ductile iron GGG40/50, EN-GJS-400/500

floating ball

ABS / NBR / st.st. AISI 304

gasket

EPDM

painting

epoxy

DNL mm.H mm.D mm.Weight kg.
5029041516522
6529041518530
8029042520030
10053048022052
150656515285109
200790615340196

DN

Nominal pressure

Test pressure MPA

Max working pressure Mpa

mm

mm

Bar

Body

Seat

50-200

16

2,4

1,76

1,6

50-200

25

4,0

2,75

2,5

DN of pipeline

DN of air valve

< 200 mm

DN 50

200 mm - 250 mm

DN 80

300 mm - 500 mm

DN 100

600 mm - 900 mm

DN 150

1000 mm - 1200 mm

DN 200

> 1200 mm

DN 250 o 2 x DN 200